Indiana does not issue a statewide master HVAC technician license, so there is nothing to transfer. Here is Connecticut's standard path for out-of-state applicants.

Your origin state does not issue a statewide license at this level, so there is no license to transfer. The destination's standard out-of-state path is shown; expect to meet it in full.

Reference only, not legal advice. Rules change; confirm with the licensing board before you apply. Full disclaimer.

Contractor (S-1) by equivalent out-of-state license (all states)

Your out-of-state credentials give no advantage. You meet the destination's requirements from scratch.

A master HVAC technician or HVAC/mechanical contractor licensed in any other state applies under DCP's 'Heating Contractor - Equivalent Out of State License' path. DCP reviews a single out-of-state license for equivalency to the S-1: it must have required 576 classroom hours with a curriculum matching Exhibit A and 12,000 on-the-job hours (8,000 as an apprentice plus two years as a licensed journeyperson); the limited D-1 class needs 8,000 OJT and 432 classroom hours and the B-1 needs 6,000 and 288. The applicant submits a copy of the license, an official license verification, the laws and regulations that set the requirements met to obtain it, and the scope of work for that license, with the non-refundable $150 application fee. If approved, the applicant must pass both the S-1 trade exam and the Business and Law exam through PSI ($59 per portion) and then pay the $150 initial license fee; the out-of-state license does not waive either exam because Connecticut has no reciprocal agreements. An applicant whose license is not found equivalent must document the classroom and OJT hours directly under the equivalent experience and training path, where out-of-state journeyman service counts if DCP finds it comparable (CGS 20-334a(a)(1)(A)).

The out-of-state license page does not restate the exam requirement; it follows from the Heating, Cooling and Sheet Metal Work Licenses page, CGS 20-334a(a)(1)(A) and the PSI bulletin, which states that all contractors must pass a Business and Law examination and a trade examination. CGS 20-333a allows licensure without examination only where the other state reciprocates for Connecticut licensees, and DCP states no such agreements exist. Whether DCP treats an out-of-state 'master HVAC' license (rather than a contractor license) as the S-1 equivalent depends on the hour and curriculum comparison; DCP publishes no list of accepted titles. EPA Section 608 is not mentioned on the DCP pages but applies federally to anyone handling refrigerants.

At a glance

Trade exam
Required
Law / code exam
Required
Out-of-state hours
Count toward eligibility

What you must already have

  • Your Indiana license must be active and in good standing.
  • The out-of-state license must be equivalent: it required 576 classroom hours matching Exhibit A and 12,000 OJT hours for the S-1 (D-1: 432 classroom / 8,000 OJT; B-1: 288 / 6,000)Only one out-of-state license is reviewed for equivalency.
  • You must document at least 12,000 hours of qualifying work experience.8,000 hours as an apprentice plus 2 years (4,000 hours) working as a licensed journeyperson; journeyman service outside Connecticut counts if DCP finds it comparable.

What you'll do to get licensed in Connecticut

  1. 1Application fee. Pay the application fee ($150). Contractor application fee, non-refundable (CGS 20-333).
  2. 2Other. Copy of the out-of-state license, official license verification, the laws/regulations listing the requirements met to obtain it, and the scope of work for that license.
  3. 3Trade exam. Pass the destination's trade exam. S-1 Unlimited Heating, Piping and Cooling Contractor trade exam administered by PSI: 80 questions, 3 hours, 70% to pass, open book (D-1: 70 questions, 3 hours; B-1: 50 questions, 2 hours).
  4. 4Law / code exam. Pass a law, rules, or code exam. Connecticut Business and Law exam (PSI): 50 questions, 2 hours, 70% to pass, based on the NASCLA Contractors Guide to Business, Law and Project Management, Connecticut 6th edition.
  5. 5Exam fee. Pay the exam fee ($59). PSI fee for the trade portion (same fee for retakes).
  6. 6Exam fee. Pay the exam fee ($59). PSI fee for the Business and Law portion (same fee for retakes).
  7. 7License fee. Pay the license or certificate fee ($150). Initial license fee for a contractor's license after passing both exams (CGS 20-335); renews annually for $150, expiring August 31.
  8. 8Other. EPA Section 608 technician certification (Type I/II/III/Universal) to handle refrigerants; federal, does not expire.

Published fees on this path total $418, excluding exam-vendor fees, bonds, and insurance.

What you'll need to buy or arrange

Exam preparation

Most boards contract PSI, Prov, or ICC for exams. Check which code edition the exam is written to before buying a prep course.

  • Trade exam
  • Law / code exam
  • Exam fee · $59
  • Exam fee · $59
  • Other

How Connecticut licenses master HVAC technicians

Connecticut master HVAC technician · “S-1 Unlimited Heating, Piping and Cooling Contractor

Statewide license

Verified September 15, 2026· 6 sources

Issued by Connecticut Department of Consumer Protection, Occupational and Professional Licensing (Heating, Piping, Cooling and Sheet Metal Work Examining Board)

Connecticut has no license titled 'master HVAC'; the top-tier personal credential is the S-1 Unlimited Heating, Piping and Cooling Contractor, issued by DCP to an individual (DCP licenses individuals, not companies) and permitting all heating, piping and cooling work under CGS 20-330, pulling permits and contracting with the public. Limited contractor classes cover narrower scopes, chiefly the D-1 Limited Warm Air, Air Conditioning and Refrigeration Contractor and the B-1 Limited Gas and Oil Burner Contractor. A new S-1 applicant needs 576 classroom hours matching DCP's Exhibit A curriculum and 12,000 OJT hours (8,000 as an apprentice plus two years, 4,000 hours, working as a licensed journeyperson), reachable through two years as a Connecticut journeyperson, equivalent experience and training, or an equivalent out-of-state license, and must pass both the PSI S-1 trade exam (80 questions, 3 hours, 70%) and the Business and Law exam (50 questions, 2 hours, 70%). CGS 20-334a(a)(1) expressly allows journeyman service performed outside Connecticut to count if DCP finds it comparable. DCP states that Connecticut does not have reciprocal agreements with any other jurisdiction. Fees are a $150 application fee, $59 per exam portion and a $150 initial license fee; licenses expire every August 31 and renew for $150.

Moving to ConnecticutLeaving Connecticut

Why Indiana has nothing to transfer

Indiana master HVAC technician

Licensed by cities and counties

Verified September 15, 2026· 14 sources

Indiana has no statewide master HVAC, mechanical contractor or HVAC contractor license and no state HVAC board; the Indiana Professional Licensing Agency's list of regulated professions contains no heating, air conditioning or refrigeration trade, and Indianapolis's exam information states that licensing is at the discretion of each municipality. The master-level credential exists only locally and under varying names: Indianapolis/Marion County licenses Heating and Cooling Contractors (Air Conditioning A, B, D, Refrigeration and High Pressure Steam) whose craft license holder passed the Prov exam, Allen County (Fort Wayne) issues an HVAC Supervisors License (Air Conditioning A or B, Sheet Metal C), Evansville licenses Master Heating, Ventilating and Air Conditioner Installers and Master Refrigeration Installers by local examination, South Bend registers HVAC contractors on proof of a passing ICC National Standard Master Mechanical exam, and Terre Haute issues a Mechanical license to contractors employing a NATE, HVAC Excellence, RSES, Experior or Indianapolis-certified person. An out-of-state master HVAC or mechanical contractor license carries no state-level recognition in Indiana. Indianapolis is the only jurisdiction with a published reciprocity procedure, and it turns on the exam rather than the state: a license earned on a Prometric/Experior or Prov exam with a 70% score, certified by the issuing agency, can be accepted by the Board of Heating and Cooling Examiners. Elsewhere a master must apply in each city or county where they will pull permits, which in practice means holding an ICC or Prov national exam score or passing the local exam, then meeting that jurisdiction's bond and insurance rules. EPA Section 608 certification is required for refrigerant work in every jurisdiction.

How local licensing works in Indiana

How local licensing works. Indiana regulates plumbers at the state level but has never created a state HVAC or mechanical contractor license. Each city or county building department decides whether and how to license HVAC contractors and master-level installers, and there is no statewide portability rule. Prov (Indianapolis) and ICC/Prometric (South Bend, Terre Haute) national exams are the most portable credentials inside the state.

Indianapolis / Marion County. The Department of Business and Neighborhood Services licenses Heating and Cooling Contractors in five types: Air Conditioning A (unrestricted), Air Conditioning B (25 tons cooling / 500,000 BTU heating, boilers to 15 psig steam), Air Conditioning D (5 tons / 300,000 BTU), Refrigeration, and High Pressure Steam. A craft license holder submits an exam packet ten business days before the monthly Board of Heating and Cooling Examiners meeting: application, resume, employer letters verifying five years of HVACR experience (education may substitute in part), three industry reference letters, EPA certification card, driver's license; after a board interview the applicant sits the Prov exam and needs 70%. The business then files a $5,000 surety bond (obligee the Consolidated City of Indianapolis, expiring 12/31/2027), a $500,000/$100,000 (or $500,000 combined) liability certificate naming the City-County as additional insured, and workers' compensation proof. 2026 fees: new license holder $377 (Jan-Jun) or $283 (Jul-Dec), new business license $247 or $185 (none for sole proprietors), renewals $247 each; licenses expire December 31 of odd-numbered years. Reciprocity: the board may accept a comparable license from any municipality or government agency if the issuing agency certifies directly to the Department that the license is current and unsuspended, the license was issued on a standardized Prometric (formerly Thomson Prometric / Experior / Block) or Prov exam passed with at least 70%, and the vendor verifies the exam is equivalent to the Indianapolis exam; the applicant still documents five years of experience, three references and EPA certification, appears before the board, and then licenses with bond, insurance and fees.

Fort Wayne / Allen County. The Building Department's HVAC Supervisors License (Air Conditioning A without BTU limit, Air Conditioning B up to 500,000 BTU heating and 25 tons cooling, or Sheet Metal C) requires four years and 7,000 hours as a journeyman in the same line of work (or eight years and 14,000 hours of documented OJT plus 30 days as a licensed journeyman) and a passing examination administered by the Building Commissioner or an approved testing facility; hydronic and low-temperature refrigeration work is reserved to Non-Sanitary Piping licensees. The supervisor qualifies an HVAC Contractors Business Registration ($90; supervisor license $25). Section H grants reciprocity subject to the trade's guidelines and minimum qualifications, and allows the Building Commissioner to grant reciprocity at his discretion to applicants who present the necessary credentials.

Evansville. The Building Commission licenses Master Heating, Ventilating and Air Conditioner Installers (forced-air heating, air conditioning up to five tons with field piping or fifteen tons packaged, ventilation, ductwork and sheet metal; boilers and steam or hot-water systems require the Master Steam Fitter license) and Master Refrigeration Installers. Applicants prove four years of experience with three notarized letters on letterhead (EMC 5.70.060), are approved to test by the Board of Examiners of HVAC, Steam Fitters, and Refrigeration Installers, sit the exam through Ivy Tech and must score 75% on each part of the master mechanical, sheet metal, ventilation or refrigeration exam, then receive a provisional license on paying the $300 fee and providing insurance and the $25,000 surety bond required by EMC 5.70.070; renewal is $125 ($225 for two years) with board-set continuing education. The ordinance notes the master HVAC license does not permit air conditioning work without EPA certification.

South Bend. The Building Department registers HVAC contractors (including refrigeration and hood installers) after review of an application showing at least 21 years of age, journeyman and contractor experience (education may substitute for part of four years), and a passing score of at least 70% on the ICC National Standard Master Mechanical exam (F29-N) via Pearson Vue or Prometric or a comparable nationally recognized exam approved by the Board; a $5,000 surety bond naming the City of South Bend/St. Joseph County, workers' compensation proof, a $50 application review fee and $125 annual registration are required.

Terre Haute. The Engineering Department's Mechanical license is issued to a contractor that employs at least one full-time employee certified by NATE, HVAC Excellence, RSES, Experior Assessment, the City of Indianapolis HVAC Air Conditioning Class A, or an equivalent, with a $10,000 bond ($25,000 for right-of-way work), $500,000 general liability ($1,000,000 for right-of-way work) and workers' compensation or a WCE-1 exemption; $350 original registration, $175 annual renewal.

Out-of-state holders. Only Indianapolis publishes a reciprocity procedure, and it accepts a license from any jurisdiction (municipal or state) that was earned on an equivalent Prometric/Experior or Prov exam, subject to board approval. Allen County has a discretionary reciprocity clause; South Bend and Terre Haute accept national exam scores and industry certifications regardless of where they were earned; Evansville requires its own examination. Expect to license separately in each jurisdiction and to meet each one's bond and insurance rules.

Moving to IndianaLeaving Indiana

Common questions

Do I have to take the Connecticut master HVAC technician exam if I'm licensed in Indiana?
Yes. Connecticut requires the trade exam on this path, plus a law or code exam.
What does it cost to get a Connecticut master HVAC technician license from Indiana?
Published fees on this path total $418, not counting exam vendor fees or bonds.
Do my Indiana work hours count in Connecticut?
Yes. Documented out-of-state experience counts toward Connecticut's eligibility requirements.
Does it work the other way, from Connecticut to Indiana?
Not necessarily. Reciprocity is directed. Going from Connecticut to Indiana, the mechanism is not applicable.

Sources

  1. Connecticut General Statutes Chapter 393 - Occupational Licensing (Electrical, Plumbing and Piping, Heating, Cooling...) · CGS §§ 20-333, 20-333a, 20-334a, 20-335 · Connecticut General Assembly · Statute · verified September 15, 2026§20-333: non-refundable application fee of $90 for limited licenses and journeyman-type licenses under 20-334a(a)(2)-(3) and $150 for unlimited contractor licenses under 20-334a(a)(1); competency is shown by examination. §20-333a Reciprocity: the Commissioner may grant a license without examination to a currently practicing, competent person holding a similar license from another state with substantially similar or higher requirements, but only if that state grants the same privilege to Connecticut licensees; DCP reports no such agreements exist. §20-334a(a)(1)(A): an unlimited contractor's license may be issued to a person who served as a journeyman in the trade for at least two years 'and, if such service as a journeyman was outside this state, has furnished evidence satisfactory to the appropriate state board or the department that such service is comparable to similar service in this state', and has passed the examination; (a)(2)(A): an unlimited journeyman's license requires a bona fide apprenticeship including not less than four years' experience and passing the state licensure examination. §20-335: initial license fee $150 for a contractor's license and $120 for any other license; licenses expire annually; renewal $150 contractor / $120 other. The page returned a TLS certificate error to the fetch tool on 2026-09-15 and was downloaded directly with curl to read the section text.
  2. Connecticut DCP - Heating Contractor: Equivalent Experience and Training · Connecticut Department of Consumer Protection · Agency Page · verified September 15, 2026S-1 needs 576 classroom hours matching Exhibit A ('Required courses for heating, cooling and sheet metal, hearth product and fuel gas license types') and 12,000 OJT hours; D-1 8,000/432; B-1 6,000/288. Verbatim: 'Classroom hours are required. On the job training and work experience will not be considered in lieu of the classroom requirement.' Same accepted and rejected document lists as the journeyperson page.
  3. Connecticut DCP - Heating Contractor: Equivalent Out of State License · Connecticut Department of Consumer Protection · Agency Page · verified September 15, 2026Same equivalency definition as the journeyperson page. Table: S-1 12,000 OJT hours and 576 classroom hours; S-3 12,000/576; S-7 12,000/576; S-9 10,000/576; D-1 8,000/432; D-3 8,000/396; B-1 6,000/288; B-3 8,000/360; G-1 5,000; PP-1 8,000. Classroom hours must match the courses in Exhibit A. Same one-license rule and non-refundable fee statement; does not itself state exam requirements or fee amounts.
  4. Connecticut DCP - Heating, Cooling and Sheet Metal Work Licenses (application paths, fees, renewal) · Connecticut Department of Consumer Protection · Agency Page · verified September 15, 2026Landing page for the heating, piping and cooling trades. Lists the three contractor paths (2+ years as a journeyperson, equivalent experience and training, equivalent out-of-state license) and the three journeyperson paths (Connecticut apprenticeship completion, equivalent experience and training, equivalent out-of-state license). Application fee: contractor $150, journeyperson $90, non-refundable; renewal contractor $150, journeyperson $120; licenses expire annually on August 31. States that DCP licenses individuals only, that every individual applicant must take an exam with separate fees due to the exam vendor, that the department does not pre-approve applications, and, verbatim, 'Connecticut does not have reciprocal agreements with any other jurisdiction.'
  5. Connecticut DCP - Heating, Piping, Cooling and Sheet Metal Work Examining Board · Connecticut Department of Consumer Protection · Agency Page · verified September 15, 2026Twelve-member board (contractors, journeypersons and public members) that advises DCP on licensing and examination of heating, piping, cooling and sheet metal contractors and journeypersons under CGS 20-330 et seq.
  6. Connecticut DCP - Heating, Piping and Cooling License Types and Scope of Work · Connecticut Department of Consumer Protection · Agency Page · verified September 15, 2026S-1 Unlimited Heating, Piping and Cooling Contractor: all heating, piping and cooling work as defined in CGS 20-330. S-2 Unlimited Heating, Piping and Cooling Journeyperson: same scope, working for a licensed contractor. Also defines the limited classes: D-1/D-2 Limited Warm Air, Air Conditioning and Refrigeration (no oil burner servicing), D-3/D-4 Limited Cooling, B-1/B-2 Limited Gas and Oil Burner (domestic and light commercial, up to 5 gal/hr or 500,000 BTU), B-3/B-4, G-1/G-2 gas piping, S-3/S-4, S-7/S-8, S-9/S-10 (heating and cooling up to 35 tons in buildings of 3 stories or less), PP-1/PP-2 and OE-2.
  7. Connecticut DCP Occupational Licensing - Heating, Piping and Cooling Trades Candidate Information Bulletin (PSI, updated 2/4/2026) · Connecticut Department of Consumer Protection / PSI Services LLC · Other · verified September 15, 2026Eligibility for examination is determined by the State (DCP approves the application, then PSI schedules); eligibility is valid for one year from State approval. Fee: $59 per examination portion, not refundable or transferable. S-1 Unlimited Heating, Piping and Cooling Contractor: 80 questions, 3 hours, 70%, open book. S-2 Unlimited Heating, Piping and Cooling Journeyperson: 70 questions, 3 hours, 70%, open book. D-1: 70 questions, 3 hours; D-2: 60 questions, 2 hours; B-1: 50 questions, 2 hours; B-2: 40 questions, 1.5 hours; all 70%, open book. Business and Law (all contractors): 50 questions, 2 hours, 70%, open book, based on the NASCLA Contractors Guide to Business, Law and Project Management, Connecticut 6th edition. References include the 2015, 2018 and 2021 International Codes, NFPA 54 (2012), NFPA 31 (2006/2011) and NFPA 58 (2014). The PDF was opened on 2026-09-15 through a text-extraction proxy because the direct fetch returned unreadable binary content.
  8. EPA Section 608 Technician Certification Requirements · 40 CFR Part 82, Subpart F (Clean Air Act §608) · U.S. Environmental Protection Agency · Other · verified September 15, 2026Federal requirement in every state: technicians who maintain, service, repair or dispose of equipment that could release refrigerants into the atmosphere must be certified (Type I small appliances, Type II high-pressure, Type III low-pressure, Universal). Apprentices under direct supervision are exempt. Certification does not expire; the core exam must be proctored for Universal certification. State HVAC boards commonly require it before licensure, but it is not itself a state license.

Verified dates are when a person last opened each source and confirmed the facts above. Cite the board, not us.

Report an error on this page

Related